1. Toplo bih ti preporučio da ne koristiš HyperTerminal. Ono što si polsao je skoro kompletan izlaz, ali toliko zbrljan da se pola stvari ne vidi.
2.
Code:
interface Serial0
bandwidth 64
no ip address
!
Ovo je teško nazvati konfigurisanim ruterom.
Takođe:
Code:
Serial0 is down, line protocol is down
Hardware is PowerQUICC Serial
MTU 1500 bytes, BW 64 Kbit, DLY 20000 usec,
reliability 255/255, txload 1/255, rxload 1/255
Encapsulation HDLC, loopback not set
Keepalive set (10 sec)
Last input never, output never, output hang never
Last clearing of "show interface" counters never
Input queue: 0/75/0/0 (size/max/drops/flushes); Total output drops: 0
Queueing strategy: weighted fair
Output queue: 0/1000/64/0 (size/max total/threshold/drops)
Conversations 0/0/256 (active/max active/max total)
Reserved Conversations 0/0 (allocated/max allocated)
Available Bandwidth 48 kilobits/sec
5 minute input rate 0 bits/sec, 0 packets/sec
5 minute output rate 0 bits/sec, 0 packets/sec
0 packets input, 0 bytes, 0 no buffer
Received 0 broadcasts, 0 runts, 0 giants, 0 throttles
0 input errors, 0 CRC, 0 frame, 0 overrun, 0 ignored, 0 abort
0 packets output, 0 bytes, 0 underruns
0 output errors, 0 collisions, 37856 interface resets
0 output buffer failures, 0 output buffers swapped out
0 carrier transitions
DCD=down DSR=down DTR=up RTS=up CTS=down
Ako pogledaš poslednju liniju. DCD je down, to znači da nema "carriera" na liniji, tj. da se modemi "ne drže". Ako nema modema, tj. ruteri su vezani back-to-back, koji od njih treba da daje "clock" liniji?
Bojim se da ovde nije problem do rutera, već do njegove nekonfigurisanosti. U to ime, šta tačno treba da postigneš? Morao bi da nam ispričaš malo više o samoj mreži, tj. kako ona treba da izgleda, pa da se onda bacimo na rešavanje problema.
Marko.